Protect your critical assets and ensure business continuity with advanced fire suppression systems designed, installed, and maintained by FST Systems. From tailored clean-agent installations (Novec 1230, FM-200, Inergen) and CO₂ systems to water mist and foam solutions, we provide rapid, automatic fire extinguishment with minimal damage to equipment or contents. BAFE-compliant servicing, real-time monitoring options via Nimbus Digital, seamless UK regulatory compliance, and 24/7 peace of mind—serving Chester, Wrexham, and the North West & North Wales.
0333 444 0032
Operations@fstsystems.co.uk
Installation follows your fire risk assessment, Approved Document B, and relevant standards (e.g., BS EN 12845 for sprinklers):
Systems must activate reliably (e.g., sprinklers only on heat, not smoke), with heads unobstructed and coverage uniform. Professional design/commissioning ensures no gaps; reassess after changes (e.g., new racking, processes, or occupancy). Signage and zoning aid fire service response.
Fire suppression systems (e.g., sprinklers, gaseous, water mist, foam, or kitchen-specific) control or extinguish fires automatically or manually, complementing detection and manual extinguishers. Under the Regulatory Reform (Fire Safety) Order 2005, provision follows your site-specific fire risk assessment—no blanket mandate exists for all commercial buildings, but Approved Document B (with 2026 amendments) requires or encourages them in high-risk scenarios (e.g., large warehouses, industrial processes, data centres, or where escape/travel distances are extended). Common types:
Not universally—no, the Regulatory Reform (Fire Safety) Order 2005 does not mandate suppression in every non-domestic premise. The Responsible Person must implement "general fire precautions" (Article 4/17) based on fire risk assessment, which may identify suppression as necessary for suitable protection (e.g., in high fire-load warehouses, flammable liquid storage, or where passive measures alone are insufficient). Approved Document B (Volume 2 for non-dwellings) recommends or requires sprinklers in specific cases (e.g., large industrial units or where extended travel distances apply). Non-compliance risks enforcement notices/fines if suppression is deemed essential but absent. High-risk premises (e.g., data centres, chemical storage) often need it for insurance, best practice, or Building Regulations compliance—always base decisions on a current, competent risk assessment.
Per BS EN 12845 (sprinklers), BS 5306 series (other systems), and RRFSO (maintenance duty):
Records must be kept on-site; faults rectified immediately. The Responsible Person is legally accountable—professional servicing (e.g., via BAFE/LPCB schemes) demonstrates due diligence and supports insurance/audit compliance.
Repair or replace immediately if:
Upgrades align with evolving standards (e.g., 2026 BS EN 12845 updates for warehouses/high-rise, or shift to modern agents/tech). Batteries/pumps often need replacement every 5–10 years; full system review every 10–15 years or post-alterations. Use competent installers/technicians; document all work to prove compliance under the Regulatory Reform (Fire Safety) Order 2005 and avoid enforcement.